Fluid Power World

  • Home
  • Technologies
    • Hydraulics
      • Cylinders & Actuators
      • Filtration/Contamination Control
      • Fittings, Couplings & Adapters
      • Fluids
      • Fluid Conditioning
      • Hose & Tubing
      • Pumps & Motors
      • Related Technologies
      • Sealing
      • Sensors & Gauges
      • Valves & Manifolds
    • Pneumatics
      • Air Preparation & Regulation
      • Compressed Air Technologies
      • Cylinders & Actuators
      • End Effectors & Grippers
      • Fittings, Couplings & Adapters
      • Hose & Tubing
      • Sensors
      • Vacuum
      • Valves & Manifolds
  • Engineering Basics
  • Trending
  • Resources
    • Digital Issues
    • Pneumatics Tech Toolbox
    • Podcasts
    • Subscribe to Fluid Power World Print Magazine
    • Videos
    • Webinars / Digital Events
    • White Papers
  • Women in Engineering
    • Women in Fluid Power
    • Women in Engineering
  • Design Guide Library
  • Classrooms
    • Hydraulic Filtration
    • Pneumatics Classroom
  • Advertise
  • SUBSCRIBE

Compressed air fail: Big/small comparison

By Paul Heney | June 13, 2025

Share

During an audit, a compressed air professional noticed an interesting characteristic. While a 300-hp compressor was used to supply an average of 800 cfm during production activity, he noticed the compressed air flow to the plant fell to about 130 cfm during non-production times on weekends. He also noticed that the plant had a 75-hp compressor that was perfectly capable of supplying this flow but was rarely turned on.

Running a 300-hp lubricated screw compressor in load/unload mode at light load might seem like a good way to ensure capacity, but it’s a costly mistake — especially when the actual demand could be handled by a smaller compressor. In load/unload control, a compressor continues to spin even when not compressing air. And during unload, the motor still consumes about 35% of its full load power just to idle. For a 300-hp machine, that means burning 90 kW worth of electricity — even when no air is being produced. Unfortunately, due to mis-adjustment, the existing compressor consumed 185 kW while unloaded!

In contrast, a properly sized 75-hp compressor will spend more time in efficient loaded operation and far less time idling. Its idle power is normally about 20 kW, about 20% of the power typically consumed by the 300-hp compressor. In this case, when the smaller compressor was switched on for a test, the energy consumption was 50 kW compared to 160 kW for the larger compressor. This is a 68% reduction. Possible savings would be about $27,000 per year if a timer system automatically switched on the smaller compressor on weekends.

Fig. 1. A 300-hp compressor supplying about 130 cfm in this case consumes 157 kW, while a smaller 75-hp consumes about 50 kW supplying the same load. Yet, the 300-hp runs most of the time during low weekend loads, wasting power.

By using a compressor that matches the demand, it is possible to reduce unnecessary energy consumption, shorten idle periods, and minimize mechanical wear. A smaller compressor is also easier to cycle efficiently and typically requires less costly maintenance over time.

Right-sizing matters a lot! If your facility needs only 75 hp worth of air, running a 300-hp compressor in load/unload mode is like driving a semi-truck to deliver a pizza. The costs add up — and fast.


Filed Under: Air Compressors, Air Preparation, Components Oil Coolers, Compressed Air Technologies, Engineering Basics, Pneumatic Tips

 

About The Author

Paul Heney

Current Digital Issue

Where are we in the tariffs tug-of-war? It feels like we’ve been talking about tariffs for months now, with the constant, will they or won’t they take effect? Josh Cosford penned an opinion piece a few weeks ago on this very topic, sharing his thoughts from north of our border as we waited for impending…

View Back Issues

Subscribe!

Fluid Power World is written by engineers for engineers engaged in designing machines and or equipment in Off-Highway, Oil & Gas, Mining, Packaging, Industrial Applications, Agriculture, Construction, Forestry, Medical and Material Handling. Fluid Power World covers pneumatics, mobile hydraulics and industrial hydraulics.

Fluid Power Design Guides

fluid
“fpw
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, tools and strategies for Fluid Power Professionals.

RSS Featured White Papers

  • Moving fluid power forward
  • High-force linear motion: How to convert from hydraulic cylinders to electric actuators and why.
  • A technical comparison: Performance of pneumatic cylinders and electric rod actuators
Fluid Power World
  • Hose Assembly Tips
  • Mobile Hydraulic Tips
  • Pneumatic Tips
  • Sealing & Contamination Control Tips
  • About us
  • Contact Us

Copyright © 2025 WTWH Media LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media
Privacy Policy | Advertising | About Us

Search Fluid Power World

  • Home
  • Technologies
    • Hydraulics
      • Cylinders & Actuators
      • Filtration/Contamination Control
      • Fittings, Couplings & Adapters
      • Fluids
      • Fluid Conditioning
      • Hose & Tubing
      • Pumps & Motors
      • Related Technologies
      • Sealing
      • Sensors & Gauges
      • Valves & Manifolds
    • Pneumatics
      • Air Preparation & Regulation
      • Compressed Air Technologies
      • Cylinders & Actuators
      • End Effectors & Grippers
      • Fittings, Couplings & Adapters
      • Hose & Tubing
      • Sensors
      • Vacuum
      • Valves & Manifolds
  • Engineering Basics
  • Trending
  • Resources
    • Digital Issues
    • Pneumatics Tech Toolbox
    • Podcasts
    • Subscribe to Fluid Power World Print Magazine
    • Videos
    • Webinars / Digital Events
    • White Papers
  • Women in Engineering
    • Women in Fluid Power
    • Women in Engineering
  • Design Guide Library
  • Classrooms
    • Hydraulic Filtration
    • Pneumatics Classroom
  • Advertise
  • SUBSCRIBE